Guo, X., Lee, K., Wang, Z. and Liu, S, “Occupants’ satisfaction with LEED-and non-LEED-certified apartments using social media data“. Building and Environment, 2021, 206, p.108288.

Chao Wang, Fan Zhang, Julian Wang, James K. Doyle, Peter A. Hancock, Cheuk Ming Mak, Shichao Liu, “How indoor environmental quality affects occupants’ cognitive functions: A systematic review“. Building and Environment, 2021: 107647.

Liu Yang, Xueni Wang, Minghui Li, Xiang Zhou, Shichao Liu, Hui Zhang, Edward Arens, Yongchao Zhai,”Carbon dioxide generation rates of different age and gender under various activity levels“. Building and Environment, 2020, 186: 107317.

Edward Arens, David Heinzerling, Shichao Liu, “Advances to ASHRAE Standard 55 to encourage more effective building practice“. Advances to ASHRAE Standard 55 to encourage more effective building practice[J]. 2020.

Shichao Liu, Zhe Wang, Stefano Schiavon, Yingdong He, Maohui Luo, Hui Zhang, Edward Arens, “Predicted percentage dissatisfied with vertical temperature gradient“. Energy and Buildings, 2020, 220: 110085.

Jovan Pantelic, Shichao Liu, Lorenza Pistore, Dusan Licina, Matthew Vannucci, Sasan Sadrizadeh, Ali Ghahramani, Brian Gilligan, Esther Sternberg, Kevin Kampschroer, Wellbuilt for Wellbeing Project Team, Stefano Schiavon, “Personal CO2 cloud: laboratory measurements of metabolic CO2 inhalation zone concentration and dispersion in a typical office desk setting“. Journal of exposure science & environmental epidemiology, 2020, 30(2): 328-337.

Zhe Wang, Kristen Warren, Maohui Luo, Xuchen He, Hui Zhang, Edward Arens, Wenhua Chen, Yingdon He, Yunpeng Hu, Ling Jin, Shichao Liu, David Cohen-Tanugi, Matthew J.Smith. “Evaluating the comfort of thermally dynamic wearable devices“. Building and Environment, 2020, 167: 106443.

Yibin Yang, Boyuan Zhang, Qilin Feng, Hao Cai, Mingrui Jiang, Kang Zhou, Fei Li, Shichao Liu, Xianting Li, “Towards locating time-varying indoor particle sources: Development of two multi-robot olfaction methods based on whale optimization algorithm“. Building and Environment, 2019, 166: 106413.

Shichao Liu, Stefano Schiavon, Hari Prasanna Das, Ming Jin, Costas J. Spanos. “Personal thermal comfort models with wearable sensors“. Building and Environment, 2019, 162: 106281.

Qilin Feng, Hao Cai, Fei Li, Xiaoran Liu, Shichao Liu, Jiheng Xu, “An improved particle swarm optimization method for locating time-varying indoor particle sources“.  Building and environment, 2019, 147: 146-157.

Ali Ghahramani, Jovan Pantelic, Matthew Vannucci, Lorenza Pistore, Shichao Liu, Brian Gilligan, Soheila Alyasin, Edward Arens, Kevin Kampshire, Esther Sternberg, “Personal CO2 Bubble: Context-dependent Variations and Wearable Sensors Usability“. Journal of Building Engineering, 2019, 22: 295-304.

Zhe Wang, Maohui Luo, Hui Zhang, Yingdong He, Ling Jin, Edward Arens, Shichao Liu, “The Effect of a Low-Energy Wearable Thermal Device on Human Comfort“. 2018.

Shichao Liu, Zhe Wang, Yingdong He, Maohui Luo, Hui Zhang, Stefano Schiavon, “Local thermal discomfort caused by temperature stratification at whole-body thermal neutrality“.  2018.

Shichao Liu, Ming Jin, Hari Prasanna Das, Costas Spanos, Stefano Schiavon, “Personal thermal comfort models based on physiological parameters measured by wearable sensors“. 2018.

Wenhua Chen, Shichao Liu, Yunfei Gao, Hui Zhang, Edward Arens, Lei Zhao, Junjie Liu, “Experimental and numerical investigations of indoor air movement distribution with an office ceiling fan“. Building and Environment, 2018, 130: 14-26.

Ming Jin, Shichao Liu, Stefano Schiavon, Costas Spanos, “Automated mobile sensing: Towards high-granularity agile indoor environmental quality monitoring“. Building and Environment, 2018, 127: 268-276.

Ming Jin, Shichao Liu, Yulun Tian, Mingjian Lu, Stefano Schiavon, Costas Spanos, “Indoor environmental quality monitoring by autonomous mobile sensing“. Proceedings of the 4th ACM International Conference on Systems for Energy-Efficient Built Environments. 2017: 1-4.

Hideyuki Amai, Shichao Liu, Atila Novoselac, “Experimental study on air change effectiveness: Improving air distribution with all-air heating systems“. Building and Environment, 2017, 125: 515-527.

Yunfei Gao, Hui Zhang, Edward Arens, Elaina Present, Baisong Ning, Yongchao Zhai, Jovan Pantelic, Maohui Luo, Lei Zhao, Paul Raftery, Shichao Liu, “Ceiling fan air speeds around desks and office partitions“. Building and Environment, 2017, 124: 412-440.

Shichao Liu, Jordan Clark, Atila Novoselac, “Air diffusion performance index (ADPI) of overhead-air-distribution at low cooling loads“. Energy and Buildings, 2017, 134: 271-284.

Guangyu Cao, Shichao Liu, Brandon E Boor, Atila Novoselac, “Dynamic interaction of a downward plane jet and a cough jet with respect to particle transmission: An analytical and experimental study“. Journal of occupational and environmental hygiene, 2017, 14(8): 618-631.

Shichao Liu, Stefano Schiavon, Alan Kabanshi, William W Nazaroff, “Predicted percentage dissatisfied with ankle draft“. Indoor air, 2017, 27(4): 852-862.

Shichao Liu, Atila Novoselac, “The effect of deflectors on Air Diffusion Performance Index of adjustable diffusers: Cooling condition (RP-1546)“. Science and Technology for the Built Environment, 2016, 22(1): 67-74.

Shichao Liu, Atila Novoselac, “Air Diffusion Performance Index (ADPI) of diffusers for heating mode“. Building and Environment, 2015, 87: 215-223.

Guangyu Cao, Shichao Liu, Brandon E Boor, Atila Novoselac, “Characterizing the Dynamic Interactions and Exposure Implications of a Particle-Laden Cough Jet with Different Room Airflow Regimes Produced by Low and High Momentum Jets“. Aerosol and Air Quality Research, 2015, 15(5): 1955-1966.

Shichao Liu, Atila Novoselac, “Air Diffusion Performance Index (ADPI) of diffusers for heating mode“. Building and Environment, 2015, 87: 215-223.

Shichao Liu, Atila Novoselac, “Transport of airborne particles from an unobstructed cough jet“. Aerosol Science and Technology, 2014, 48(11): 1183-1194.

Shichao Liu, Atila Novoselac, “Lagrangian particle modeling in the indoor environment: A comparison of RANS and LES turbulence methods (RP-1512)“. HVAC&R Research, 2014, 20(4): 480-495.

Shichao Liu, Guangyu Cao, Brandon E Boor, Atila Novoselac, “A Protected Occupied Zone Ventilation System to Prevent the Transmission of Coughed Particles“. 2014.

Shichao Liu, CM Mak, JianLei Niu, “Numerical evaluation of louver configuration and ventilation strategies for the windcatcher system“. Building and environment, 2011, 46(8): 1600-1616.